What the purpose of transient fault recoredr in substation
Answer Posted / thowsif_emerson
Transient Fault Records in Substation we are using a DDFR
(Distributed Digital Fault Recording) System:-
Transient Fault Records (also known as Oscillography
records) that are recorded in protection relays will be
retrieve by the DDFR and stored in its internal memory
space. All Transient Fault Records will be archived using a
naming convention that will make it easy for users to
relate the Transient Fault records with a particular
substation fault. Each record will be stored with a name
that includes the exact date and time that the record was
initially triggered. If the Transient Fault record was
originally recorded in the relay as a COMTRADE file, the
DDFR will store this record in its native format; if the
protection relay stores it’s record in another format, such
as a CSV file, the DDFR will automatically convert this
file into the COMTRADE-1999 format so that the record can
be analyzed using a standard COMTRADE viewer.
Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
what is the power factor used by the PHCN in nigeria? 2. what is the difference between an alternator and generator. 3. Generation of poweris in KV but how is transmission is in MW. 4.If the transmission of power is 20,000MW how can it be increaesed to 80,000MW
what is stper motor
How do we calculate the Out put voltage of generator, after the excitation is being given?
What happen Grid EARTH plat got cut.
Why the field rheostat is adjusted such that the voltmeter reads 380V
What is difference between unity power factor wattmeter and upper power factor wattmeter? In short circuit test of transformer the wattmeter used is unity power factor type or upper power factor type wattmeter?
WHAT IS THE MEANING OF BALANCED / UNBALANCED IN STABILIZER TYPES.
Is vtg is controlled by the resistor? if else how much?
I completed my BE EEE degree 2006 .... which license should i apply .... ?????
Draw torque - speed curve and load curve of induction motor? mark operating point ?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
what is the electrical?
Define the term Capacitance and Inductance?
What is the size of a 60 watt and 80 watt tubelight?
What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance