what is the difference between a feeder and a cable?
Answer Posted / nitin narwal
u can consider every feeder as a cable but u cant say same
as in case of cable.
a feeder is related with load i.e current or we can say
that current capacity i t can bear.
e.g
1.trunk feeder
2.sub feeders
a trunk feeder is a feeder which comes directly 4m the
grid,,,,for e.g lets say 11kv
sub feeders are originated from trunk feeder e.g a11 kv
line is connected to a bus bar and 4m that several 11 kv
feeder are originated.
3*300 size cable we use in feeders now days for 11kv
3 means 3 core and 300 sq mm cross section area of each
core.
while in case of distribution we generally relate it with
voltage regulation,,and it is again with the help of cables.
so we have concluded that all are cables but when we
specify their roles we just call them with seprate names
Is This Answer Correct ? | 2 Yes | 7 No |
Post New Answer View All Answers
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
In a flange coupling, the flange bolts are designed for
why transmission is only 3 phase and not 2 or 4 or poly phases
what happen when increase or decrease size of lamp,light.glass.
State magnitude criterion.
On what basis do you decide the ONAN (Oil Natural air natural) or Dry type transformer for a project?
Vibromotor 252MV 1/4HP2P..what is mean by 252MV?
A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?
What is the function of the circuit breaker failure relay?
what is residuel magnetism. and how order lead acid batteries for 24 volt. emergency lighting system.
How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9
why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.
Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet
i want to put single phase load on scott connected transformer,eventhough how to balance the transformer.
dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour