which motor is suitable for traction? why?

Answer Posted / manoj tyagi

D.c series motor coz high starting torque but after the
invention of scr induction motor become more popular coz it
can easily controlabe, no commutator n brush problems also
using im regenrative breaking system can b used which save
a huge amount of power . In metro n also in conventional
engines im is used in these days

Is This Answer Correct ?    28 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?

3605


Why arc quenching is used in Diode ?

1569


What will be the fault current of any system when its generation is 10% of BASE generation( FUll Load )?Will is 10% or the same as full base calculation?

1425


If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1419


Approach of a cooling tower is the difference between temperatures of what factors?

617






give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model

2236


i karmveer bharti persuing b.tech . plz send me syllabus and name of reference books. for preparation of section eng.

1655


What are the disadvantages of hydropower?

657


What is the difference between a 3 winding and 2 winding Potential Transformer

1822


Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?

676


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1579


Star Delta Diagram with full description

1897


How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.

1588


How could I get a certificate of competency as Electrical Supervisor? I have completed By BTech in Electrical this year(2012) for VJTI Mumbai Maharashtra. Is it compulsory to be produced while joining?

3008


Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

1175