what is the apt definition for kirchoff's current and
voltage laws?
Answer Posted / arunmozhi
kirchoff current law:
sum of current equal to ozero
kirchooff voltage law:
sum of voltage = sum of current
| Is This Answer Correct ? | 1 Yes | 8 No |
Post New Answer View All Answers
why can we use cosine wave instead of sine in ac supply as both have same rms vale and ripple factor
why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?
HOW WORK HEAT PLATE EXCHANGER
Hello to all, Please someone can send me HPCL ELECTRICAL Engg. Sample papers to me? Its urjent....my email address is.... raviasiapacific@gmail.com
Briefly describe your ideal job?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
We have two APFC panels in same station. I need how to connect CT in two APFC panels.can we take one CT in series connection or two separate CTs.
WHAT IS THE FAULT WHEN 100HP TURBINE MOTOR TRIPS, LIST THE FAULTS AND ITS TRABULESHOOTING TIPS.. MY AUTO TARNSFORMER STARTER TRIPS
what material is the electrical housing wire made of? is there any difference for the telephone lines?
What does the a,b,c of 95a,95b,95c relays denotes?
Why water bubbles when D.C. Current is passed through it? Why not when A.C. Current is passed?
1. what is usage for power factor in industries?? 2.why we need to monitor power factor??
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
Difference between Earthing Truck & Earthing trolly for HT panel
What kind of socket shall be provided for window type air conditioner with cooling capacity upto 18000 BTU/hr