What are the rating wise protections required for
Generators from 600KVA to 2000KVA
Answer Posted / ashutosh
On the Basis Of Rating
there are following types of protection is required
1) Overvoltage Protection
2) Undervoltage Protection
3) Over Current Protection
4) Under Current Protection
5) Overheat Protection
Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram
how can maintain the power factor and why and this is how do work tell us
What is the loss of transformer of 220kv/11kv, 63/80 MVA and 18.05% impedance
How phase displacement change in the over current relay coils.
HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?
What is the capacitance values of 132,220,400 & 765 kV current transformer
How many sprinklers should be in one pipe line?
Which device of PlC does share load between DG sets when DG are running in perallel?
a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5
how current is reverse from its normal direction during the fault?
In synchronization circuit what is the function of Interposing voltage transformer(IVT)and Reverse voltage transformer(RVT)
Can we test the alignment of End shield and stator of turbogenerator without rotor insertion? Also how to fix maintain the alignment at site installation?
ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH
What is the IS standard for MCCB to be use (As per capacity of AMP)& for ACB also.
what is saturation kit?which use above 15 kw motors panel side.