what will happen if the secondary of current transformer
kept open....

Answer Posted / sudhar

if secondary is kept open,the rated current inthe primary
will be induced in the secondary side.due to open ckt,the
curent wil be zero.so high voltage will pass which will
burn the secondary coil and the devices connected to it

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much earthing frequency is capable?

1582


sir, i'm preparing for hpcl exam officer trainee pls tell me how the exam ques paper pls pls

1786


which IS or IEC is used for earthing,breakdown voltage of transformer oil, hv/pd testing and all type of electrical testing

2216


tell me about roaster switch .& what is the function in transmission & distribution?

2172


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

2149






What does bode plots shows?

681


A TRANSFORMER 440/400V,DELTA/STAR CONNECTED.THE NEUTRAL CONNECTED WITH GROUND CABLE THAT IS DIRECTLY CONNECTED TO THE PANEL,FROM PANEL IT IS CONNECTED EARTH PIT.IS IT RIGHT? IF IT IS RIGHT LEAKAGE CURRENT AFFECTED.SECONDATY IS PROTECTED WITH EARTH LEAKAGE RELAY.

1712


What OPGW is better than Microwave or PLCC???

3656


What is Harmonics how it is produced and what is the method to control the same

1774


I am apply the AAI. So i want electrical sample question paper in technical with answer my id is vijayjobsmart@gmail.com

2210


33kv Rated output avilable in market (any where in india)

1631


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1452


What is the meaning of loop in transformer

1201


I have motor 1500 HP and , 4160 V , 60 HZ , then i need the rating of transformer which can feed that motor ??

1405


What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.

1818