IS there any mechanical connection between the field winding
and armature winding of a dc generator?
Answer Posted / guest
no
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?
when we decide to use soft starter drive or vfd drive in mcc to operate apump?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Why AC current leads voltage in capacitor and how?
What are the weight of 800KV DA,DB and DC type tower ?
What is Annunciation?
anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?
Explain cmrr?
What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer
if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer
What is the Minimum winding resistance of motors ( small & big)? referance range
what will be the min and max voltage flow from neutral to earth?
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
What is time response of the control system?
How much minimum insulation required between 11kv/3.3kv transformer windings?