Why Power factor is different - different in all three
phase of a 3 phase nduction motor.
Answer Posted / nagaraj n salimani
Power factor depends on the connected load on that perticular
phase due to heavy inductive load ( Induction motor)but you
are telling it is different in all three phase it is due to
the mismatch in the phase impedence in the motor winding
Is This Answer Correct ? | 13 Yes | 0 No |
Post New Answer View All Answers
what is feeder bay?
33kv Rated output avilable in market (any where in india)
What is an iron loss or core loss pi?
The gauge indicates the number of amps, but what about voltage? How voltage rating (for wire or fuse) determined?
How many energy meters can be connected on a 15VA Voltage transformer. please send a calculation sheet.
we have a 2.5hp Starite electric motor water pump,the elec motor burned out,we need to replace starting capacitor(old capacitor specs erased),what microfarad rating capacitor do we need? 110-125V
how to calculate cable size in diffrent loads?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
I WANT TO INSTALL LIGHTING ARRESTOR ABOVE 20 FEET HEIGHT INDUSTRIAL BUILDING. NOW IT WAS 15 FEET HEIGHT HOW MUCH DISTANCE IT WILL COVER & HOW TO CALCULAT THE DISTANCE COVER BY THE ARRESTOR
What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.
does a DG set has low fault level as compared to that of a transformer.If yes then why.
ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant
1 “earthing” for bonding of equipment and circuits to common plant earth electrode potential, 2 “protective earthing (PE)” when this bonding is required for personal safety provisions 3 “grounding” for interference suppressing bonding of screens, sys-tems with ground level 4. low-impedance earthing ? 5.primary earthing system and secondary earthing system what is that? 6.earthing electrode or mesh net earthing electrode ? very confusing , simple but very informative help required ? i will be very very thankful to you guys.
what are factors comes under relay setting (distance relay 7sa52) under OPEN DELTA VTs connection??
Why derating factor os applied on Cables?