Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In electrical cables what is U and U0 refers?

Answer Posted / hemant choudhary

U0-Rated voltage
U-Peak Voltage

Is This Answer Correct ?    4 Yes 32 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?

2151


We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.

1859


what is the clear formula to calculate cable size for a load

1966


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1886


how much winding resistance of 0.75kw to 12.5kw 3ph sqwiralcage induction motor?

3004


why incomer bay is required before transformer bay if there are more than 1 nos. of transformer bay.

3115


why normally Generator rating are between 11Kv to 22Kv?

4668


What will be the current drawn by HT motor, if low voltage is applied.. any formula to calculate the LT amps of HT motor.?

1455


1.what is mean by 8/20 micro sec waveshape

2233


In TNC switch, is there any 1NO+1NC block ? and if we move over closing position, is ther any affect on trip position or vice versa?

2246


What is the de rating factor of cable? What is the importance of the de rating factor in cable selection?

2096


draw vector diagram and +ve,zero sequence diagram of symmetrical three phase fault.

2032


What is the instrument to check the rotating diode fuse of alternator in running conditions?

2476


how to select fuse rating for a 3-phase motor ???

1802


Difference between low impedance and high impedance Restricted Earth Fault

3125