Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why the Voltage rises when Leading Power Factor is occurs?

Answer Posted / aymaan

the effect of armature reaction in leading pf case is
magnetising ie to assist the main flux hence as the total
flux increases so the emf also increases

Is This Answer Correct ?    22 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to choose size of the cable w.r.to current carrying capacity ...

2214


Define closed loop control system.

1091


how much allowable resistance that can be difference in motor all coils?

2349


During underground cabling in landscape area what did we cover the cable with to prevent the electric shock & protect the cable?

1882


What will happen if the armature resistance is in minimum position and the field resistance is in maximum position while starting the motor

1628


Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

2186


What are the necessary components of the feedback control system?

1229


why we take movement of rotor always in counter-clockwise direction in 3-phase induction motors?

1962


On what basis the the size of Lightning arrester for buildings are selected ?

1661


1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?

2007


what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.

2340


What is meant by system?

1074


71ohm,111ohm,95ohm,179ohm in calculate the total ohm in series circuit

1686


In radial network the source is fed from 1 end both ends at central

2136


Can anyone please provide me details of MCCB/Contactor/SFU rating calculations for a motor feeder..for example 50 kw.. not from type-2 cordination chart. i want manual calculations..

2595