IS there any mechanical connection between the field winding
and armature winding of a dc generator?

Answer Posted / manojkrishnan

There is no mechanical connection in between field and
armature windings . The winding of the field is wound on the
stator cores while that of the armature is wound on rotor
cores. There must be a narrow gap in between the stator and
rotor cores ( say 2mm ) so as to rotate the rotor freely .

Is This Answer Correct ?    24 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?

1768


How much load can take a 16 mm aluminum cable 3 phase

1260


BRIEFLY EXPLAIN THE STORAGE CLASSES AND THEIR TYPES IN C

1859


. What is Electrical Life & Mechanical Life of Circuit Breaker? 2. What is Electrial Life & Mechanical Life of Magnetic Contactor? 3. What is RCD, RCCB & RCBO? 4. What is the Between defferance of RCD, RCCB & RCBO?

2834


What is the instrument to check the rotating diode fuse of alternator in running conditions?

2009






how i calculate the syncrones generator NGR resistance .if we have a 6mw generator line voltage of generator 11kv also line current 393.3 ampere.

1662


what is the range of maximum DOL and SDS can be use for pump and fan application

632


sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.

1495


what is DRP panels?

1681


Please define ohm’s law for a.c (alternating current)?

644


what is interfacing in computer studies?

1252


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2264


which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant

1471


a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5

1182


tell me some type of questions throught which i can prepare for exam and do my best

1548