what is the meaning of servo motor. In trains, what type of
the motors we are using at the bottom of each compartment

Answer Posted / salil

Servo Motor is one which functions based on the feedback it
receives from comparator and other feedback devices for
accurate functioning, in both the directon. it is used as
control device. In trains, traction motors are used,
normally are d.c. series motors.

Is This Answer Correct ?    14 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the Resposiblity of Electrical Utility Engineer

2415


Write the current equation in series RLC circuits.

632


what is the meaning of vcc

1896


What is the current carrying capacity of 0SWG,3SWG,10 & 12 SWG solid bare overhead copper conductors?

2956


What are the main advantages of bode plot?

693






I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1260


can we choose current transformer secondary, to calculate residual flux in a power transformer, so as its saturation is close to the saturation level of power transformer?

887


How to calculate energy stored in an inductance?

647


what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:

1522


what are the differant std sizes of cable trenches?

1529


How to calculate flow of water delivered by pump when pressure & size of pipe line is given

1778


Write a note on Treatment for electric shock.

1412


TO CALCULATE THE RESISTANCE OF GRR OF HT MOTOR 400KW WHEREAS STATOR VOLTAGE 6.6KV AND ROTOR VOLTAGE 705V AND ROTOR CURRENT IS 346A.

4941


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1276


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

1508