why current increases when voltage decreases in ac
system
Answer Posted / ashish rai
First of all of you notice that p=vi* cos(phi)
Another thing is that for running ac system 10% of voltage
fluctuation is allowed from electricity board.
Hence V is nearly constant factor.
I*cos(phi) is the variable factor hence with variation in
current power factor of system will change not voltage.
If any body is making wrong it plz clarify it.
Is This Answer Correct ? | 6 Yes | 6 No |
Post New Answer View All Answers
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?
how harmonics generated in induction furnance? how minimise it?
How much inductance or resistance require as a starter in series with induction motor of specific capacity(e.g. 5 hp) ? What is formula for it ?
what is advertised hop count
What is the basic principle of operation of alternators/dc generators?
What is knee point voltage?
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
how power trnafor from 1 point to another point in bus bar ya transmission line( voltage trnasfer from 1 point to another poin)
how much GROUND & NEUTRAL VOLT maintain in data center.
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks
Define piezo-electric effect?
what is the voltage regulation for unity and zero power factor?
Explain different types of d.c motors? Give their applications
What is the difference between UPS & inverter ? which UPS is better and whos got the edge ? what is the difference between & inverter ? which UPS is better and whos got the edge 12 V , 24 V , 36 V etc what are the advantages of 12 V, 24 V , 36 V etc and what are the disadvantages of 12 V, 24 V, 36 V etc thanks