Motor and transformer working with same principle so why
motor rotates while transformer not?
Answer Posted / avtar singh
coz it is static device it has no rotatry
part....................
Is This Answer Correct ? | 17 Yes | 3 No |
Post New Answer View All Answers
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
Whether amorphous core transformer is commercialized or not:Name of company making amorphous core transformer and what are different rating?
can you send me the placement papers of electrical engg. from companis like NTPC,DRDO,IOCL,HPCL,BPCL etc.?If,plz send as soon as possible.Thanks.
Explain Creepage Distance of Insulator
to vary valtage from 0 - max a variac is necessary . so how to design for high power applications nearly about 200KW power
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?
What is VSCF windelectrical system?
how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?
Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.
What are the characteristics of negative feedback?
what is metering cum synchronizing panel and how it is used?
1.25 kg of hydrogen are burnt with stiochiometric air, the mass of air in kg required is
two phases with neutral supply can be taken in 3C X 10 sq.mm cable .
On what cycle does thermal power plant operate?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?