1. What means HART communicator / where it is used /
how to use it?
2. Types of Thermocouples and its temperature ranges /
output of thermocouple?
3. Types of RTDs and its temperature ranges / output
of RTD?
4. Idea about Temperature Transmitters?
5. Difference between Analog and Digital signals?
6. Difference between “2 wire” and “4 wire” system /
instruments?
7. Difference between “Potential” and “Potential free”
contact?
8. Types of flow meters / transmitters?
9. Types of level transmitters?
10. Difference between “Power/Control” cable
and “Instrument” cable?
11. What means “shield” and “screen” in cables / how it
is useful?
12. Draw a schematic of closed loop circuit of flow /
level / pressure / temperature?
13. Idea about calibration of Control valve /
positioned / I/P?
14. How to bypass a digital/analog signal in PLC/DCS by
hardwire and software?
Answer Posted / rajesh
1.HART is Communication Protocal.it is used to Communicate
the Field Instruments for measuring and Calibrating purpose
2.K Type : 0-1370 degrees
J Type: 0-700 degress
B Type: 200 -1800 deggress
R type: 200 - 2450 degrees
Output of Thermocouple is DC Potential (milli volts)
3.Platimum RTD :PT-100 Range:-270 to 600 degress
Output of RTD is Resistance
4.Temparaure tranmitters
it will receive the sinal from sensor (thermocouple /
RTD) and this signal will convets to 4-20mA or 0-20mA
5.Analog Signal is contioues measuring signal ie it's
measuring Range is 0 to 100%
Digital signal is a Binary form ie. Its state is Either
High (1) or Low(0)
6.in 4 wire Tranmitter Have Seperate exitation Supply is
for its Operation and Output taken for seperately.if the
Tranmitter Elecronic Cercuit is drawing More than 4 ma of
current then it will apply the 4 wire scheme.
in 2 wire Tranmitter working supply and its output is
taken in same cable.ie its working supply is lessthan 4 ma.
Is This Answer Correct ? | 63 Yes | 6 No |
Post New Answer View All Answers
how to calibrate load cell
How to Calibrate Level Switch in field
PT RTD Range: -200 to 500 degree celsius If I configured in DCS Lower range and Upper range . In face plate it shows red colour due to overa range how was the characteristics look If the temperature is more than operating range. how was the characteristics look . whether its in Resistance vs Temperature curve is Linear or Non linear
How to Calibrate Vortex Flow transmitter in field
How does your previous experience relate to the job you are applying for ?
why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.
full process of gas turbin?
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
Pl send the model question paper of mahagenco account officer post
what is temperature compensation?
how to control pid
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
What are the types of control valves available