How much voltage we get between two wire of 4 to 20 ma
output? Is this voltage up or down respectvice to 4 - 20
ma ?

Answer Posted / shankar rao

1 TO 5Volts,

Is This Answer Correct ?    1 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?

634


How can i copy program (parameter) from mm440 (V.F.D.) by using BOP?

2284


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2202


What are the application of bernoulli’s theorem?

684


ORP sensor working principle?

1527






hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?

1654


what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration

1565


how to check earthing,what is minum ohms for proper earthing

1512


we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.

2157


Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

1745


how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.

2015


What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.

2503


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

877


Capacitance, resistance ( colour coding ), parallel & series circuits.

1734


What is the right procedure for adjusting the gap voltage of bently nevada vibration sensor?

14408