How do you think they do earthing or grounding in ships and
aeroplanes?
Answer Posted / ram niveth
neutral is connected to the body of aircraft/ship.so body
is considered as earth for sensing earth fault
Is This Answer Correct ? | 14 Yes | 13 No |
Post New Answer View All Answers
if we install two earth pits with a clear space of 5m without any interconnection,by checking the digital multimeter will it show continuity between earth pits? If so what would be the approx. value
What is difference between SMC supportg and Glass Fibre Reinforced Plastic Support.
hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.
What do you mean by a current transformer?
If short circuit ratio is high is it bad or good for a machine then tell the reason...
What is open delta Xformer? It's adavntages & Use?
I have a reading off 1.5ohms at my mem my main c/b is rated at 40/6 amps in a domestic house and i was told to change it to a b curve c/b is this ok
Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.
please send me latest & previous years question papers for IOCL Technical level questions
difference between main metering kiosk and check metering kiosk
why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)
Refernce currents are to be generated using refernce cueernts how can this be done??
What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA
How to synchronization will be done between two DGs ?
I am going to appear for the RRB Chennai junior Engineer online exam. Please send me the previous exams question papers (also solved) to my mail id: rrkhandhar@yahoo.com