How does a VOLTAGE OPERATED DIFFERENTIAL RELAY work??

Answer Posted / sukhvinder

differential relay which operates on two or more similar
quantities i.e voltage,current.

in this relay under normal condition, no voltage flow
through coil i.e vi+v2=0 but in abnormal the differnce of
two voltage i.e v1+v2 will not equal to zero. so that
voltage will flow through the coil further protection of
equipment/devie/system etc.

Is This Answer Correct ?    4 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is called limb of a transformer?

611


Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

1599


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1671


What is transister define the transister ammiter ,base, colector.

1734


When a square wave is applied to primary of a transformer then what will be output wave form of secondary ?

1588






How do you determine the size of transformer radiators in a transformer?

1439


how to calculate power consumption in slip ring motor at different step

1712


Starting times for soft starter & power factor is thier any standard or datas available in manufactures list. Kindly suggest.

1469


why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)

2008


How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

1530


what are the assumptions made in swineburne's test?

1695


sir i ve applied for hindustan petroleum and power grid india ltd..and the exams on feb 22.can you pls send model papers and tell how to prepare for those.i need to get into any of these for sure.....

1747


how to prepare the technical test

1623


At what speed an electric car can run with 2 HP motor of weighing 400 kg?

1314


I have motor of 3 H.P. How i found the rating of capacitor use in it in single phase motor..???

2141