tell me about the instrumentation,what is the actual need
of it ?what are the characteristics of a IC engineer ?
Answer Posted / raj
instrumentation is the measurement and control of any
physical parameter that changes w.r.t time.Its need is to
control any time varying quantities in the industies.The
characteristics of the inst.engg is to predict the changes
in the parameters and control accordingly.
Is This Answer Correct ? | 29 Yes | 2 No |
Post New Answer View All Answers
Operational amplifiers
What is the use of single seated valve?
What is the basic difference between Modbus and CAN Open Protocols
What is mean by analytical instrumentation?
Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability
What is the difference between uv and ir scanners? and what is the workig principle of both
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon
How the warning lamp of a charging-system is activated ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?
field bus transmitter calibration procedure tell me
How to Calibrate Flow Switch in field
What is the PLC configuration in Cement industry?
what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...