What is mean by diversity Fator?

Answer Posted / jaykaran

DIVERSTY FACTOR IS DEFINED AS THE RATIO OF SUMMATION OF ALL
MAXIMUM DEMAND FROM LOAD SIDE TO THE MXIMUM DEMAND ON POWER
SUPPLY SYSTEM..HENCE IT IS ALWAYS GREATER THAN 1..BECAUSE
IT IS THE RARE CASE WHEN ALL CONSUMERS ON POWER SYSTEM
REQUIRE THIER MAXIMUM DEMAND.

Is This Answer Correct ?    19 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

from which subjects most of the technical que will b asked for hpcl(electrical).pls help me

1573


i've iocl interview.. if you know the interview process please give me information..

1448


How to calculate the External Resistance required for 60HP slipring motor in case no any data of the Motor is available???

1606


Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?

1426


what is the Pickup/drop off ratio in BCPU relays

4159






prove that power consumed in 3 phase delta system is 3 times as compared to 3 phase star system

1723


LET ME NOW MORE ABOUT icu and ics for circuit breaker. how we calculate the rating of circuit breaker and i c u and ics values

2438


What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.

1958


What are the basic components of the feedback control system?

616


What are protections for dty type transformers

1378


What happened when capacitor connect series in ac circuit?

968


How to select transmission line type (i.e. 11kv or 33kv) for new established industries

1599


why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?

4655


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1198


I want to put this query to SENIOR & EXPERIENCED ELECTRICAL ENGINEERS. 1)I want to know about the control circuit diagrams for control panels. I found it difficult to understand. Is there ant booklet through which we can learn the circuit diagrams? 2)I want to learn about conduiting, laying cables, preparing cable schedules and various techniques which is the part of building infrastucture(construction field). I don't have any experience in this area. I have experience in control panels only. that's why i am not getting any opening in building infrastucture (construction field).Can I get the job in this field as Trainee Engineer? How to enter this field? I need job in PUNE

1486