What is the amount of no load current of 630 kVA tranformer
voltage ratio 11kV/440V ?
Answer Posted / dennis
No Load current will depend on Core Grade, Core Thickness,
Flux Density, Frequency and the quality of workmanship (how
good are gaps closed).
| Is This Answer Correct ? | 15 Yes | 0 No |
Post New Answer View All Answers
how we decide wire gauge for ac or dc coil and what is the basic diff. B/w these two coil?
how to calculate percentage impedence at 75 deg C at normal tap
Why neutral cable carry current.
at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)
how a.c. genarator control power factor when its conected to grid supply by incrising or decresing excitation voltage.
Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.
Plz tell me how we can find that particular company has vacancy or not
Explain about Dubai electrical sysaem? Explain about Dubai drinking water system? Explain about Dubai Burj tallest building Electrical,Water.etc.. maintenance system?
how many current required for hypo test
hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused
what is mean by dual digital protection in the relay field?
Starting times for soft starter & power factor is thier any standard or datas available in manufactures list. Kindly suggest.
What is the permissable nutral current of three phase system as per IS standards?
what are the specifications we must look at to select a relay for any capacity motor?
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.