Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In A.C systems, fuse is placed in phase-in order to
disconnect the circuit during faulty condition.
But, what is the reason for putting "LINK" in neutral
istead of connecting through (same) wire.

Answer Posted / s k sudhakar

TO ATTEND ANY PROBLEM IN A PARTICULAR SYSTEM, THAT SYSTEM
IS REQUIRED TO BE ISOLATED. IF LINK IS NOT PROVIDED COMLETE
ISOLATION IS NOT POSSIBLE.

Is This Answer Correct ?    7 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?

2066


WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.

2198


can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you

2011


How PSV sizing being done

2337


Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?

3053


why high speed tripping relay will be used in tripping circuit why not normal relay

1372


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1949


how can maintaince the acb contactor moveing and fixing kit

2086


How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

1084


Can anyone explain me about the RLC based Impulse high voltage generator and how to and operation of Series resonant High voltage reactor...?

1948


what is the purpose of shading ring or shading coil in electrical equipments.

4484


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.

1999


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

2092


What is deference between MCB & MCCB & ISOLATOR

2130


how can i use REF and diffrencial relay both in 1 CT core for transformer protection?

1877