What do you mean by linear and bilateral network?

Answer Posted / shivani

linear network is directional network;means all parameter
depends on direction
Bilateral means non-directional. it 's parameter doesn't
depends on direction.

Is This Answer Correct ?    35 Yes 37 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What do you mean by Stimulastion Test in Diesel Genarator / Why & when it's conducted ?

1215


can i use 2000/5A Clamp meter to measure HT cable

1567


Which is the oldest hydropower plant in india?

684


Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks

3421


how to erect roof control panel?

1538






What are the types of transformers according to the arrangement of iron cores?

618


The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.

938


hi frnds...pls send me aptransco previous papers .....pls..pls,,,(madhar.rocking@gmail.com)and suggest me some websites

1707


66kv under ground cable how to layaing in ground any special case two ckt r runing

1542


i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.

1191


What is the difference between relays and contactor construction wise?

1614


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1103


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

1537


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1504


1.what is the reason for transformer and lightning arrester blast in 33kv system

2581