why does same amount of current flow in the circuit inspite
of any number of resistances in the circuit?
Answer Posted / chowndaryaa sehar
Because current always takes the least resistive path.
Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.
mccb service sittings be done?
sir, Is their any measuring unit of knoking? please explian?
How harmonic block test are conducted on relays ( Siemens,Areva ect )power transformer using omicron kit?
During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?
BSNL TTA EXAM QUESTION
pls tell me about ups internal connection & we have given only 3 phase supply to ups system how get 4 wire (R Y B N )
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What is the theoretical reason for the size of a zig zag grounding transformer to be 1.732 times less than that of a wye-delta grounding transformer used for the same application?
i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?
How to set a Zone 1 distance relay for distribution feeder?
if you are in a software company,then why do you want to come in a core company like sail, ntpc(where lots of trouble like tension but you have a good life in a it company) ?
What is the purpose of stablization resistor in high impedance bus bar protection
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter