how tubelight circuit is connected and how it works?
Answer Posted / ramesh pachamal
A choke is connected in one end of the tube light and a
starter is in series with the circuit. When supply is
provided the starter will intrupt the supply intermittant
cycle of AC. Due to the sudden change of supply the chock
will generate around 1000volts . This volt will capable of
to break the electrons inside the tube to make elctrone
flow. once the current passess through the tube the starter
circuit will be out of part. now there is no chande of
supply causes chocke voltage normalised and act as minimise
the current.
Is This Answer Correct ? | 179 Yes | 30 No |
Post New Answer View All Answers
How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.
Why the arms of delta in a delta-wye power transmission system are kept constant??
When can we take Neutral as common neutral link?
What is relation between transmission lines & Communication lines ?
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m
How to calculate the sag on transmission Lines.
why we use circuit breakers for switching instead of normal switching device?
Why does the rotor rotate?
I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field
Why does amplifier gain reduce?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
When we need up only in o/p 440v, so why we use directly in 11kva in input?
i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value