what is the relation b/w KW and KWH? plz explain with
example.

Answer Posted / srij21

KW is the maximum capacity in terms of power for which the
machine has been designed for. Just like 106cc,150cc,180cc
in the two wheelers.

KWH is the amount of energy consumed by the machine in one
hour. just like 75 kilometer per litre ,60 km / litre.

I think it will be sufficient

Is This Answer Correct ?    28 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the reason the main breaker is trip during the motor is running? (some time the breaker is not trip)

1299


is there any device that works properly accept relay, it may be fuse but if i want fuse of 33kv 300 amp it is avaliable, pls give me details

1563


Why hydropower stations are preferred solution for meeting peak loads in grids?

568


what is the sludge current

1555


condition Autotrip facia come on control panel of electrical transmission line?

1083






i have completed deee and i've (June2012-feb 2015 experience in electrical maintenance in pvt ltd company.company having HT & LT electrical power.how to apply electrical C-license ,NOW I was resigned my job,what are requirements of applying for c-license

1302


nwhat are the main Components of servo motor?

1613


I have a small system with two motors that are running on 380 vac, 60 hz. These motors are expensive and I usally get them from Brazil. I am adding another motor to the system, but I want to purchase a 480 vac, 60 hz motor to use. It will be on a VFD that is rated fro 380 thru 480. Is this posible and will I have to use a larger motor and derate it?

1526


how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

1840


can anyone provide me a amf panel control wiring using ec-2 relay?

1720


What is the difference between rulling span and wind span of of an Over Head Transmission Line?

1835


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2067


How do you select the pickup value of the relay?

806


what are the specifications we must look at to select a relay for any capacity motor?

1560


Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

1581