Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

deference between DCS and PLC including date processing and
architacture.

Answer Posted / yogesh

1.PLC USED FRO REPALCING RELAY LOGIC. FEW YEAR AGO, THE
MAJOR DIFFERENCE BETWEEN PLC AND DCS WAS SCANNING TIME. BUT
IN TODAY TECHNOLOGY PLC SCANNING TIME HAS REDUCED.

2. WHEN YOU USE PLC , YOU NEED SCADA SYSTEM. BUT FOR DCS
SYSTEM YOU NEED NOT TO BUY OTHER SCADA SOFTWARE.

Is This Answer Correct ?    12 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is 1:1 redundancy ?

2390


There are two chlorination tonners both are connected to two pressure swithes and the pressure switch is connected to SOV which operates the valve to changeover the tonner selection i.e if pressure one tonner goes low the other tonner should come in line if it is inautomatic selection design a circuit using relays ?

1973


Explain types of valves?

1063


what is the calibration procedure for magnetic flow meter @ onsite

1665


List three types Level Gauges with their working principles

2094


How r the calculation of process line mpm.

4810


What is 3 selection available when configure the burnout protection for controller

2710


How to Calibrate Temperature Switch in field

1322


What is defferent betwen ESP &PCP PUMP .HOW IT IS WORK?

2489


What is Alpha & Beta fctors related to Orifice Plate & its relation with flow?

3385


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

2281


HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?

3527


how do we commission inergen system?

1966


In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.

1985


Dear Sir/Madam,im going to attend Hpcl written exams on feb 17th in instrumentation stream..can anyone send me the HPCL model papers and pattern of HPCL ....i ve not yet attended anything in HPCL...so i dont know how it comes...so just i need some model test papers and pattern ..pls help me friends...

2122