ALLInterview.com :: Home Page
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   Errors
   Testimonials Refer this Site  Refer This Site to Your Friends  Site Map  Contact Us      
   
 
Categories >> Engineering >> Electrical Engineering
 


 

 
Question What is the d/f between DOL & star delta starter & automatic
star delta starter?
 Question Asked In Companies :: ACC, Dalkia, Indeco, Wipro,     < I also faced this Question! >
 Question Submitted By :: ravi
  Answer Posted By  
 
Answer
in dol starte the motor is directly fed from the line and
in star delta starter ther motor is started initially from
star and later during running from delta

Is This Answer Correct ?    319 Yes 45 No


 
  niranajn
 
View All Answers
 
 
Please Help Members By Posting Answers For Below Questions
 
 Question Views   Select
 
Transformer cores are laminated in order to A simplify its construction B minimize eddy current loss C reduce cost D reduce hysterisis loss 591
What is Auto Mains Failure Panel & Auto Synchronizing Panel 169
A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why? 318
HOW TO CALCULATE THE REGULATION OF 100 AND 25 KVA TRANSFORMER 229
Can anybody tell abt concrete encased earthing or grounding? 407
RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV 324
How can calculate the earthing strip of Copper/GI for rating of 30kV,discharge current 10KA Lightning arrester. 384
I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details. 488
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning. 28
what is meant by tranformer impedance? 735
According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided. 1567
the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage? 417
Wt is the function of reactive power? How it generates & consume though resultant is zero? 229
write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain; 375
In the ACB breaker capacity is 2000Amp but this each phase taken 1250 But total beldibg load is 600amp or 700amp watt is the problem 307
E-Mail New Answers        Answer Selected Questions