Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why all voltage levels are the multiples of 11KV?

Answer Posted / johince

Multiples of 11 has no role decoded from form factor and
anything like that (I believe). the relation to form factor
is just a coincidence.
In early days when technology has not advanced this much,
the transmission lines consumes around 10% of the total
power transferred. Normally loads are designed as multiples
of 10 or 100 KW. So the generation done for required load
power + transmission loss. ie 11KW, 110KW etc. So generated
voltage also was designed as multiples of 11.
Hence the insulators has to be designed for these volatges
and hence the form factor coincidently derived as 1.11.

Is This Answer Correct ?    35 Yes 56 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is capacitor voltage transformer?? how it is different from potential transformer?

2197


Why is the frequency not changed during transformation of electrical energy in a transformer?

1417


does a DG set has low fault level as compared to that of a transformer.If yes then why.

1993


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1779


Define super node?

1222


can any one provide me a connection wiring diagram for a DG set control panel along with BOM?

2223


What is VCB? where it is installed at SP. What is SP?

2189


DIFFERENCE BETWEEN NORMAL TRAFO AND THRISTER TRAFO?

2625


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1807


what is maxemo work permit procedure

2216


How to choose the vector group for the step up and step down transformers??? Tell me the which vector group is suitable for step up and step down transformers and whats the reason to choose and whats the benefits???

2289


For the requirement of a furnace of temperature range up to 1200 oC using silicon carbide rods, What is the required rate of transformer needed (please do it with all details)?

1957


what is the physical connection of a analog i/p to a analog i/p module (ab plc)and through a analog o/p module(ab plc) to a analog o/p . and how all the process control by scada

1939


What Normal(Tangent) towers and Tension(Cut-point) Towers?

6226


Why mostly the HV side of transformer has Delta?

3230