Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is plc?

Answer Posted / t.pitchaikannu

PLC(Programmable Logic Controller)
----------------------------------
* It is a controller which is used to control machines ,
process,or total industry
* It is programmable ,depending upon application we can
change the program ,download and run the controller.
* They are so many logics are used to write a programme
1.Ladder Logic(LD)
2.Instruction List(IL)
3.Function Block Diagram(FBD)
4.Structure Text(ST)
5.Sequential Flow Chart(SLF)
* From this name itself it used to control the
applications by programming the logic.

Is This Answer Correct ?    32 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1796


What is instrumentation control?

1165


where i can get training in INTOOLS and PDMS in Delhi-NCR OR north part of India. please reply with ur ans. at arunsamkaria@ymail.com

3546


what is maxdna ?. explain about the software details.

4383


what can of fault ofently come in vibration mesurement?

2150


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2269


Turbidity analyzer working principle ?

1788


how u choose thermowell lenght n pnumatic C/v size?

2114


What is Cavitation in a control valve?

2066


what is the difference between scaler and vector drive

2187


I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann

2266


what is performance test.need defination

1718


What is the use of single seated valve?

1077


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

2197


Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.

2122