what type of protection and safety req. in the 220kv
substaion and area around the substation
Answer Posted / raman jain
Always wear industrial safety halmet.
Don't raise hands.
don't use umbrella in rainy days.
always go with one collouge.
don't walk on tranches.
never operate isolators with out wearing hand gloves.
and rest is GOD.
Is This Answer Correct ? | 10 Yes | 6 No |
Post New Answer View All Answers
How to protect sensitive loads such as Dosing pumps inside a factory from voltage surge/voltage fluctuation.
Why generation voltage in thermal power plant is between 11kv to 33kv?
Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?
what are the reasons of CT circuit faulty in busbar protection scheme?
how harmonics generated in induction furnance? how minimise it?
what is integrated ac contact circuit
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
Why the standard of ambient teperature mentioned as 40 degree celcius in machines.
dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
Define super node?
Difference between RCCB, RCBO and ELMCB.
What is the RME and explain the full form and what is the RME work?
what is sustainable current of any conductors . a bare busbar or pvc cable has different sustainable current .
Why two phase welding machine is used instead of three phase welding machine.