what happen when dc shunt motor field is sudden open in
running condition
Answer Posted / ramana
motor function will be stopped and its armature rotation
comedown slowly
Is This Answer Correct ? | 4 Yes | 39 No |
Post New Answer View All Answers
1.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?
Dear friends, i would like to know that what is the exact function of 'exciter winding' & 'aux winding' in Alternator?
what happen as when voltage drop(or may decrease) ? in case of atomic base theory?
Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.
Is any generator is developed which is operated with out diesal or other expensive source?
What is the function of attenuator in cro?
what is feeder bay?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
determine two methods to find loose connection in operational electrical system?
What is the difference between the transmission line and distribution line?
what happens to the supply voltage if there is any change in frequency?
What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?