What is the effect if power factor is above 1 or unity.
Answer Posted / balaji
The power= Voltage*current*power factor... So when the
power factor is equal to or naer 1 the input voltage and
curret is fully utilised.. so losses..But we can't made the
Power Factor more than 1 in Practical life..
| Is This Answer Correct ? | 19 Yes | 15 No |
Post New Answer View All Answers
What are the different losses In a de mac1une'! t.xplam
Explain about c.t?
sir i had plane to do some project with the base of hopkinson test in AC supply its possible
If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Why can't we parallel Voltage transformer secondary circuits?
What is lifting power for 1 wb/m2 and 1 A magnet?
What is the Load Capacity of Panther conductor (0.2) and dog conductor (0.2)
Any one can explaination about calibration with rotating sub standards?
What is the basis for selecting Vk/2 or Vk/4 for REF and Differential protection of Transformer and What is the significance of magnetising current
Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?
75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?
PLEASE TELL ME ABOUT QUESTION PAPER OF UPCL ENTERENCE EXAM.
what is draiv work
What are the parameters of water ( Water quality )to be monitored in Centralised HVAC ( water cooler chillers )