If induction motor load is incresed motor speed
decrases.But in syncronous motor load incrases speed
canstant why?

Answer Posted / bhavin

simple yaar, in i.m. speed is inversely proportional to
load , and in synchronous motor speed is always constant u
cant change it ,if want to do that motor will be trip.

Is This Answer Correct ?    11 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the effect of pi controller on the system performance?

615


What is effect of over voltage and under voltage on ACB

1402


what is size of 3phase 4wire cable to be used for 11 ton ductable A.C and how to calculate cable size for different load

3592


Explain the role of a car driver as one of a feedback mechanism.

742


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1529






Whether power factor should be high or low? Why?

663


what types of cable used in underground coal mining?

1060


How much no load current of synchronous motor

1595


What is the function of the generator exciter?

921


I want the details about BHEL company examination.Can anyone able to help me please.

1598


how indusrial diesel generator work

1471


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3047


Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you

1275


How shall i select the value of capacitor or inductor in a system?

1452


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1450