Question What do you mean by linear and bilateral network?
 Question Asked At :: disa, infosys, why we use bilateral network?, inhfhfj, optcl, automation industry,
 Question Submitted By :: sabarikumar
I also faced this Question!!    
Answer Posted By  
 
Answer
Linear Element are those element which follow the ohm's law.
Like as Resistance,Inductor&Capacitor(at relexed condition)
Bilateral network is that network in which any element of
the network gives the response in both directions e.g R,L,C
but diode gives the response in only one direction so it is
a unilateral element.

Is This Answer Correct ?    58 Yes 34 No


 
  ashok rajput
 
View All Answers
 
 
Please Help Members By Posting Answers For Below Questions
 
 Question Views   Select
 
why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ?? 431
WHAT IS ERECTION OF ELECTRICAL SYSTEM? 1284
redundant connection in contactor? 669
how we can do the insulation on secondary of ct explain and so that tan delta will within limit 291
why Lightning arrestor are made by 2 seperate stack of inslutor but why cvt are in single stack of insulator. 333
what are the application of over current relay? 1571
How I calculate the ELCB for circuit breakers? 456
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection? 265
2 v/500amp/hr to 1.80vpc at 20 degree celsious 2v/5ooamp/hr to 1.75 vpc at 77degree farren .this is the capacity of a battery .what is the meaning of this . can i get a detailed explenation 277
If rotor works in clock wise what happens 244
What is spill current in protection relays? 295
what are problems caused by the pdu in rack server 330
In a voltage-controlled current source A A current booster is never used B The load is always floated C A stiff current source drives the load D The load current equals Isc 253
what was the function of the auxillary relay? 1394
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland. 326