For a centrifugal pump if the pump is running and we close
the discharge valve what is the effect
Answer Posted / tahir
The pump start churning and this will increase the temp of
fluid and because of this impeller of pump damage due to
erosion.
Is This Answer Correct ? | 96 Yes | 19 No |