in three pin pluge there three pins one is phase and second
is earth third is nutral why nutral high diameter compare
with phase and earth

Answer Posted / gajanan

actualy earth socket has large diameter as compared to
phase and neutral.

it is for the safty.

whenever abnormal condition occures, abnormal current
should be earthed quickly and for that resistance of path
should be minimun and

resitivity= R*l/A ;
resistivity inversly prportion to area:A

so when earth socket hole be large abnormal current goes to
zero without any accident.

Is This Answer Correct ?    76 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB

2086


Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1237


How to calculate the sag on transmission Lines.

2424


How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?

1374


A system absorbs 100 k J of heat and the increase in its internal energy is 100 kJ; the work done is

770






In a single how much maximum current and watts using

1650


i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.

1870


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1217


How can we decide cable size from HT panel to Transformer? Please give you reply with some examples.

1782


what is meant by surge? what we called for high currents?

1496


1.What will be stored in online ups EPROM IC?

1602


Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.

1103


what would happen if reactive power (kvar)is increased (more)or decreased (less)? how much exact reactive power should be maintained? and what should be done for that

1780


WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES

1625


How to decide no. of Step and Kvar for APFC Panel 40 kvar MD: 33.12 KVA Avg pf : 0.8540

671