There are mainly three types of sub-stations.
1.step up/down substations-where stepping up or stepping
down of voltage has done.
2.power factor improvement sub station-where power factor
is improved by installing capacitor banks or synchronous
condensors.
3.switching sub stations- Where switching action like
switching on or off has done for maintenance purposes for
other reasons.
4.poll mounted substation, Underground substation
Is This Answer Correct ? | 31 Yes | 4 No |
Post New Answer View All Answers
Which Class insulation is prefered for the sandwich Busducts ? Why?
Between educational qualification and practical work experience, give us a brief explanation on your practical experience in your past Endeavour that you performed well to the satisfaction of your past or present employer?
In a Impedance Based Distance Relay (Quad Characteristics) - Could there be two different Line Angle(RCA) for Ph-Ph & Ph-Gnd? If So Kindly Let me Know.. Where, What are the advantages of the same?
I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks
WHAT IS counter flux IN CT?
How is the resonant peak, resonant frequency, and bandwidth determined from nichols chart?
How does HT work & Voltage required?
What is a commutator?
What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate
Why corona leads to production of Ozone and glow of the color VOILET?
what is meant by re-rolling motor? how it differs from standard motor?
Define liftable weight of a transformer? Does the total weight of transformer include oil weight?