what is the voltage between the earth & neutral
2 is there any continuity TO BE between earth & NEUTRAL

Answer Posted / kumar

therotically it should be 0V. But practically differences
lies for which upper limitis are been mentioned.
For electronic systems like telecommunication it less than
5 V, for power systems less than 100V.

Secondaly , it may connected to earth depends on what
neutral you system needs i.e. fixed or floating.
Moslty it is connected to earth for safety of personal &
euipment.

Is This Answer Correct ?    12 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I Just want do EHS Certified Certification Distance Course From Govt approved,so can any body provide me details.

1695


how much cable size required for 70 kilowatt load.

1150


which connection is safer series or parallel?usually which connection we prefer at home?

8335


What are merits & De-merits of State-Space Method? What is series programming, parallel programming, general programming & direct programming ? And, difference between these programmings Techniques ?

1938


what is PDU in transformer?? which company manufacture??

1379






why can we use cosine wave instead of sine in ac supply as both have same rms vale and ripple factor

2072


Which type of air compressor is used now a days in the market. Keeping in mind of energy efficiency and maintenance points. Relevant documents may also be sent on mentioned email ids.

1250


y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..

1531


Power Factor Correction Panel (Manual & Automatic)

1691


need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.

1313


How to checked frequency drive output voltages?

692


A jet of fluid strikes a plate What was the force required to counter it?

1467


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1155


please send me privious exam's queation papers of section engineer(electrical).

1604


what is the minimum winding resistance of 30hp compressor, to run or to switch on

1402