1. Why a DC motor starter is called 3 point starter

Answer Posted / c.balakrishna moorthy

Actually Dc motor starter are classified as two point
starter,three point starter and four point starter.
Three point starter is used in case of Shunt motor(some
cases this can be used compound motor also)
Four point starter is mainly used in compound motor.
Two point starter is used in series motor in order to make
the motor to run in safe manner.
Three points denotes Line terminal.field terminal and
armature terminal in which three points are connected.
three points L,A F.
that is the main reason

Is This Answer Correct ?    165 Yes 25 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is difference between unity power factor wattmeter and upper power factor wattmeter? In short circuit test of transformer the wattmeter used is unity power factor type or upper power factor type wattmeter?

2287


what maximum range of star & delta in hp or kw ?

1271


What are the necessary components of the feedback control system?

730


can we do the star delta connection of capacitor for 3- phase motor starter.

1540


Why line VTG = √3 phase VTG in star? How?

1174






Is a d.c.compound motor is use as a booster? how?

1651


Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain

2517


What will happen if the armature resistance is in minimum position and the field resistance is in maximum position while starting the motor

971


write a c++ code that receives an integer number and display the sum of the number and its revers integer?

1572


Name the test signals used in control system

795


What is different between Circuit breaker and Isolater?

1222


What consists of 2 or more thermocouples to be connented series?

1759


What is hipot test procedure?

1006


Sir, I have applied for the of Jr.engineer(Electrical & Electronics) & ASST. LOCO PILOT at ALL RRB BOARDS. please send me all RRB Boards solved papers in the year of 2001 tO till date. i requested send me the papers to my id as soon as possible (jet_0991@yahoo.com). (This is very urgent) Thank You,

1404


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1405