Answer Posted / kishore
LA is a non-linear resistor i.e. during normal condition it
offer high resistance but during abnormal condition
(abnormal voltage ) it acts as a low resistor thus allow
the heavy fault current and provide path to ground.
It is pointed one as charge resides/attracted by pointed
object and always placed at top of switchyard/building.
| Is This Answer Correct ? | 18 Yes | 1 No |
Post New Answer View All Answers
If a current -8+6sin6t is flowing three ammeter, one is a centre zero PMMC meter, one is true rms meter and one is moving iron meter. What are the reading of these three meter respectively?
what are the basic insulation levels & what its Unit
What is gain margin?
How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?
define the active power?
pls tell me about ups internal connection & we have given only 3 phase supply to ups system how get 4 wire (R Y B N )
please give me solution to rectify the emi(electromagnetic interference)
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
I HAVE BEEN SELECTED FOR APGENCO A.E(ELECTRICAL) 2008.HOW MUCH WEIGHTAGE FOR INTERVIEW AND WRITTEN TEST.HOW I HAVE TO PREPARE. PLEASE GIVE INFORMATION IF U KNOW.WHAT ABT G.D THIS TIME.CALL RATIO 1:2
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
hi frnds can any one help me ? plz send me placement paper of IOCL of Electrical streem .... plz send ....its urgent....
What is the function of attenuator in cro?
How do I calculate/select Droop CT ratio for various capacity of generators?
What is the high series capacitance winding on high voltage power transformer ?