what is DCS?

Answer Posted / kamran

dcs is a control system in which the controller elements are
not central in location but are distributed throughout the
system with each component sub-system under the control of
one or more controllers

Is This Answer Correct ?    134 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi i m B.E. In elect. & comm. I m workin in bio mass plant from 6 mnths as inst. Engg. but now i m in dept. Of operation as shift engg...which is best operation or inst. 4 me? M confusd..plz help and reply me..

3292


what is wave length were using ?

1485


what is function of switch, and how is it work, explain with difination

1797


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

1717


can any one tell me when ongc placement test and its forms is available????/ pls tell me if u know

1630






SOME OF YOUR QUESTIONS ARE NOT MAKING ANY SENSE SO TRY AND PUT IN A LITTLE BIT MORE EFFORT BEFORE YOU POST A QUESTION. WE WILL ONLY HELP THOSE WHO WE CAN SEE ARE TRYING TO HELP THEMSELVES.

1927


Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?

1367


how to calibrate corollaries (Mass flow meter)?

1647


pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.

2668


If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?

1627


Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?

705


principle of automatic votage regulator

1672


Isometric drawings are generated during _________________ phase of a project

1615


where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia

9335


We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.

1761