can u please give the exact ckt explaination of AC Drive
related to industries.
Answer Posted / sameer
AC drive speed control on basis speed=120F/P
F is frequency which is variable
Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
How to calibrate an pressure gauge with yantrika test bench?
i have been asked by QAFCO to appear for interview for thy post of Instrument Designer(INTOOLS)..i m engineering graduate with 5 years exp. in design engineering.Will this job profile suit me??i need all ur help n suggestions for thy same?
With N nodes and B branches what will have a network ???
Somebody tell me in what way i need to prepare for csio pgrpe(adv instrum eng)interview?what all the quest can i expect?
what is diffrance between FF & SMART, explain with difination
What are the error values can accepted in flow transmitter calibration?could u give any formula for this?
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
What is the use of single seated valve?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
how to calibrate Necleuonic level transmitter.?
dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.
any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.
Meaning of the following a. IOP- Manimum; b. IOP- Maximu,;
who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.
please send me the inteview questions in IOCL