What is min and max voltage between earth and neutral/phase
if it perfect earthing?
Answer Posted / m.mousa
This will depend on the earthing arrangment
plz check IEC 60364-5-54 Electrical installations of
buildings - Selection and erection of electrical equipment -
Earthing arrangements
Is This Answer Correct ? | 83 Yes | 41 No |
Post New Answer View All Answers
Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?
how can i determine the KVA/MVA rating of transformer precisely?? is there any standard test?????
in dc shunt motor if field winding is shorted then
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.
Why are the cores of large transformers built up of circular transactions ?
why starting current is high and resistance is almost 0 during the starting of motor dc motor...?
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
which IS or IEC is used for earthing,breakdown voltage of transformer oil, hv/pd testing and all type of electrical testing
Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
How to test REF relay testing for LV panel as per Kahramaa standard?
Name the component u would expect to find in a switchgear assembly?
Can any answer me ,What will be the range of C.T coil for L&T energy meter EM301 used for 180 kva DG set
In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?
State and define norton’s theorem?