TNS-01188: Listener cannot operate with incompatible
transport protocols
Answer / guest
Cause: Listener was configured with multiple listening
addresses with different and incompatible transport
protocols. Listener cannot operate efficiently in such
configuration.
Action: Modify the existing listener configuration by
removing the listening address that caused the error.
Configure a separate listener to listen on this address.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
QSM-02021: set operator encountered in mv
ORA-38721: Invalid file number.
ORA-14152: invalid number of partitions specified in PARTITIONS clause
ORA-03132: two-task default value overflow
ORA-23334: column string does not exist in table or column group
ORA-00290: operating system archival error occurred. See error below
ORA-09200: sfccf: error creating file
ORA-08331: Wait operation timed out
ORA-03112: a server linked as single-task cannot use SQL*Net
ORA-16756: Resource guard could not open standby readonly
TNS-12569: TNS:packet checksum failure
ORA-19641: backup datafile checkpoint is SCN string time string