ORA-16087: graceful switchover requires standby or current
control file
Answer / guest
Cause: An attempt was made to perform a graceful switchover
operation using a backup or clone control file.
Action: Convert the backup control file into a current
control file prior to attempting a graceful switchover
operation. A clone control file cannot be used for a
graceful switchover operation.