Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

VECL Interview Questions
Questions Answers Views Company eMail

A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.

2600

With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.

1987

Draw the wave shape of armature current in a generator subjected to a sudden three phase short- circuit at its terminals. Define various reactance of generator from this wave shape.

2238

A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1923

A generating system will have a total capacity of 300 MW. Find the probable forced outage when the capacity is supplied by two 150 MW units. The operating probability of all units is P=0.98 and forced outage probability rate Q =0.02 .

2644

A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

2521

Can a generator rated 400 V, 60 Hz be used in a 50 Hz System? Yes or No ? Why ?

1 2376

What is meant by load angle of an alternator? Upon what factors does the load angle depend?

3011

How do the synchronizing lamps indicate the correctness of phase sequence between existing and incoming alternators?

2197

Post New VECL Interview Questions




Un-Answered Questions

What is linear-logarithm chasm?

1034


What is angularjs architecture?

830


What effect does a very low impedance have on the Voltage regulation? On the short-circuit current?

6308


How is typescript different from javascript?

238


Why do we use inheritance in php?

1060


What is moss?

826


My question is abt backlog.I had dropped one subject in my second year, and completed this subject in the 3rd attempt, so how many backlogs i have got?1 or 3?plz sujjest the answer as soon as possible

2114


Do you wish to further pursue your studies?

1245


What are the forces which keep a flying plane in a equilibrium?

807


Can we save image in database?

989


how do you check the status of the queue in websphere mq?

958


Do we have validate write and validate field in form level?

203


How to maintain the relation between two tables in ADO.NET?

1020


how to entry of hra

2272


could anyone tell me what r real time questions been asked in interviews?i am in urgent need..thanks in advance

1906