What type of protective system we uses in L.V. distribution
panels?
Answer Posted / vel
over current and earth fault relays (2OL+1EL method)are
used for lv .
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
WHAT IS counter flux IN CT?
Which level of the Transformer oil got dielectric strengh? And why?
Explain the propagation of harmonics in the network and influence of phase angle of harmonics.
DG SET BLOCK DIGRAM
Hi, This is Laila. I am selected for syndicate bank interview. Could you please share your views and the questions asked if you have faced the interview My email id is laila_honey09@yahoo.com Please send as fast as u can.Thank You Thanks... Laila.
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
How we can change the direction of rotation of Induction motor? Prove it using graphical
why is the power generator connected as star earthed or star earthed through reactance and what its features ?
What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?
A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
What is knee point voltage of transformer?
What are the various types of rotor used in the alternators?
Any one can explaination about calibration with rotating sub standards?
How many types of colling system it trformers?