Answer Posted / pabitra choudhury
Same as the units you use for measurment of Pressure .
Absolute vaccum is zero pressure .
Vaccum meance the pressure is below atmospheric pressure.
| Is This Answer Correct ? | 15 Yes | 0 No |
Post New Answer View All Answers
i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com
Why does the radius of armature is less than the radius of pole shoe?
Advantage of LT panel vs HT panel
What are the different sign conventions used in electric circuits?
What is the type of feedback used in an op- amp schmitt trigger?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
do we use links in a dc circuit?if so what s its use in it?
what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated
What is the difference between Droop vs Isoch Control?
Explain the propagation of harmonics in the network and influence of phase angle of harmonics.
How can a equal potential zone be carried out in conductors?
What are the uses of stepper motor?
I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?
If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?
Why increase in current leads to increase in conductor temperature?