what is runout? how it is measure? which is the refrence?

Answer Posted / vennela

Runout is specified on cylindrical parts. It is
measured by placing a gage on the part, and
rotating the part through 360 degrees. The
total variation is recorded as the runout.

• Circular runout is measured at one location.
• Total Runout is measured along the entire
specified surface.

Info from :
http://engineering.dartmouth.edu/mshop/pdf/introdr.pdf

Is This Answer Correct ?    180 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how many types of suspensions are used in automobiles?

599


What does dynamics of machines deals with ?

831


Why must we pay attention when we drain steam in steam turbine. What factors are observed?

1566


What are the disadvantages of axial flow (piston type) automatic control valve compared to the conventional types (globe or diaphragm) If you are a designer/specifier, do you accept this type of valve for using in building's piping systems ?

1748


DIFFERENCE BETWEEN CODES,STANDARDS & SPECIFIFCATIONS?

1557






good book for material science and catia v 5 high scope domin to make career

905


What is the steam consumption formula?

3099


Explain the causes of the exhaust valve leakage.

1381


Tell us how do you discharge your duties in your duty post

5224


should cutouts made in main header of metal ducting be deducted from duct measurement.

1755


Explain the opening and closing of water to the bowl of the purifier

1771


what is the reason of hat and work is not conserved energy?

1413


How the bearing numbers are allocated?

1669


What do you treat in high alkalinity of boiler water?

1430


i am from karnataka can i able to apply appsc

1826